@HE VICAR - System Maintenance.
17.7 CHANGE CONFIGURATION - Version 2.1d
General Description - Change Configuration allows the user to
taylor the parameters and defaults which are used throughout
the program to their particular needs and system. The
Configuration System uses a Hidden, Read-Only file to store
the parameters listed below for use by all parts of the
program, without having to re-enter these parameters each time
the program is run. The Configuration System consists of 1
main screen, and 4 secondary screens which allow the user to
readily edit All of the parameters.
For a view of the Main Screen, see Figure 17.7
The Secondary Screens and the parameters they access are
described below:
1.) The System Parameters Screen includes:
- Company Name.
- Program File Path.
- DOS Utilities Path.
- Menu Text Color.
- Menu Background Color.
- Menu Frame Color.
- Text Color.
- Text Background Color.
- Border Color.
- Internal Printer Support.
- Use Numeric Keypad. (Turn ON Num-Lock Automatically)
2.) Control Password Screens include:
- File Maintenance Password.
- System Maintenance Password.
3.) The Printer Parameters Screen includes:
- Path to External Printer Support.
- External Printer Support Program Name.
- Internal Printer Device String.
- Default Report Length.
- Use Form Feeds.
- Write Initialization String.
- Use Condensed Print.
- Printer Error Codes:
- Off Line Code.
- Out of Paper Code.
- Printer NOT On Code.
- NOT Connected Code.
4.) The Printer Code Entry Screens include:
- Standard Initianization Codes.
- Standard Reset Codes.
- Condensed Print Codes.
- Condensed Print Reset Codes.
CHANGE CONFIGURATION - Continued.
--------------------------------------------------------------------------------
SC 2.3
The Current Settings Are:
Company Name is : Victory Computer Consultants
Printer Device Str : LPT1: ╒[ Sample Menu: ]═══╕
Default Form Length : 66 │ Menu Text │
Write Form Feeds : FALSE │ Menu Text │
Init Printer : FALSE │ │
Condensed Print: TRUE ╘════════════════════╛
Printer Init. String :
Printer Reset String :
Condensed Init. String : 15
Condensed Reset String : 18
╒[ Config File Setup: ]══════╕
Text Color: ** TEXT COLOR ** │ S ystem Parameters │
Border Color: ** BORDER COLOR ** │ F ile Maintenance Password │
│ M aint. System Password │
Background: ** WHITE on BACKGROUND ** │ P rinter Parameters │
│ I nit. Printer Codes │
│ R eset Printer Codes │
│ C ondensed Print Codes │
│ N o Condensed Print Codes │
│ W rite Parameters to File │
╘═════════════════════════════╛
--------------------------------------------------------------------------------
Figure 17.7
@PA
Configuration Menu - The Main Screen contains a menu which
provides access to all of the Configuration parameters, the
menu items and parameters they access are described below:
17.7.1 System Parameters Entry - The following is a description
of the System parameters and their defaults if any. See
Figure 17.7.1 for the layout of the System Parameters Screen.
Company Name - Name of Company using the program - this
name is printed on the top of all reports and show up on
most major screens.
Program File Path - This must be specified in order for the
program to operate properly, especially if a file is to be
viewed on the screen. Also if the program uses Overlay
files, this must be correct before the program will run.
Must contain the Drive specifier and the Path if any.
DEFAULT: \
DOS Utilities Path - This must be specified in order for
the program to allow the user to perform Backup & Restore
procedures from within.
NOTE - For the Color Parameters listed below, use the Sample
Menu on the Main Screen to determine if the colors
selected for the menu are acceptable.
Text Color - Numeric value of the color for Standard text.
DEFAULT: mono: 15 color: 14
Background Color - Numeric value of the color for the standard
background color.
DEFAULT: mono: 0 color: 0
Border Color - Numeric value of the color for the Border
text around the Editing Screens.
DEFAULT: mono: 7 color: 4
Menu Text Color - Numeric value of the color in which Menu
Text is to be displayed.
DEFAULT: mono: 15 color: 1
Menu Background Color - Numeric value of the color in which
the background of the menu is to be displayed.
DEFAULT: mono: 0 color: 15
Menu Frame Color - Numeric value of the color in which the
Menu Frame is to be displayed, also the color in which the
Editor Screen Informational Borders is displayed.
DEFAULT: mono: 15 color: 4
CHANGE CONFIGURATION - System Parameters - Continued.
Internal Printer Support - If there is no external printer
support, such as: PRINT.COM (TSR), SPOOL.COM, etc. then
this parameter must be set to YES for Internal support by
the program itself.
DEFAULT: YES
Use Numeric Keypad - Determines if the Num-Lock key is to
be turned ON automatically by the program upon start-up.
This is particularly useful on computers without a separate
numeric keypad and Cursor control cluster to ease data entry.
DEFAULT: YES
--------------------------------------------------------------------------------
Victory Computer Consultants VICAR Full A/R System SC 2.3
System Parameters:
Company Name : Victory·Computer·Consultants··
Pgm. File Path : \
Dos Utility Path : \
Text Color : 14
BackGround Color : 0 Internal Print Sup : Yes
Border Color : 4 Use Numeric Keypad : No
Menu Text Color : 1
" BKGD Color : 15
" Frame Color : 4
Available Screen Colors:
Black - 0 █ Magenta - 5 █ Lt. Green - 10
█ Blue - 1 █ Brown - 6 █ Lt. Cyan - 11
█ Green - 2 █ Lt. Gray - 7 █ Lt. Red - 12
█ Cyan - 3 █ Dk. Gray - 8 █ Lt. Purple - 13
█ Red - 4 █ Lt. Blue - 9 █ Yellow - 14
█ White - 15
F1 - HELP
F2 - Save Changes
<RETURN> for Next Field ESC - To Quit
--------------------------------------------------------------------------------
Figure 17.7.1
@PA
CHANGE CONFIGURATION - Continued.
17.7.2 File Maintenance Password - Password used for access to
the File maintenance menu of a program, if no system
maintenance function exists then this password also allows
access to the System configuration utility.
17.7.3 Maintenance System Password - Password used for access to
the System maintenance menu of a program, if used, allows
access to the System configuration utility, seperate from the
file maintenance function.
NOTE - The passwords entered ARE CASE SENSITIVE
(e.g. "password" <> "PASSWORD" <> "Password" <> "pASSWORD", etc.,
Password = Password). The entry is done using the double
entry method, if the two match, then the password is saved
in the Configuration file. If they do not match then the
password is saved to the Configuration file as a Null String
(No Password). The passwords will NEVER be displayed on the
screen at any time during entry for security purposes, this is
the reason for Entry and Validation.
17.7.4 Printer Parameters Entry - The following is a description
of the Printer parameters and their defaults if any. See
Figure 17.7.4 for the layout of the Printer Parameters Screen.
Printer Path - This is the Path to the External Printer
Support Program (e.g. Print Spooler), Such as:
"D:\PRNTR\PRINT.COM" DEFAULT: no command.
Printer Command - This is the command that is passed to the
external Program containing the filename to be printed and
any flags/switches to be passed with it. E.g.: "%F /P"
%F is the location where the filename of the file to be
printed should be inserted in the command line.
DEFAULT: no command.
Printer Device - This is the Device String which indicates
the Logical printer Port to be used by the program for
printing of its reports. Valid printer device strings are:
"LPT1", "LPT2", "LPT3", or "PRN".
The device string should be entered without the Quotes and
No colon should be entered following the device string.
DEFAULT: LPT1
Default Report Length - This is the value used by the
printer support module when printing all reports, it is the
number of lines per page. This value should be calculated at 6
lines per inch. E.g. 11" paper equals 66 lines.
DEFAULT: 66
CHANGE CONFIGURATION - Printer Parameters Entry - Continued.
Use Form Feeds - This value determines whether the Printer
module should write Form Feeds to advance to the next page
or use line feeds to advance to the top of the next form
according to Default Report Length. Also after printing a
report, if Use Form Feeds is True, then the paper will be
advanced to the top of the next form, so that it is ready
for the next report to be printed.
DEFAULT: Yes
Write Initialization String - If some specific initialization
string should be sent to the printer before printing the
reports, then set this parameter to: Yes. Common Init.
strings include: Enhanced Print, Emphasized Print, 12CPI, etc.
DEFAULT: No
Use Condensed Print - If printing of wide reports (e.g. 132
col.) is desired on standard 8.5" x 11" paper then set this
parameter to: Yes, and the printer support module will
automatically initialize the printer with the Condensed
Print Init. Code. If you are using wide paper (14 7/8" x
11") to print wide reports, then set this parameter to: No.
DEFAULT: No
--------------------------------------------------------------------------------
Victory Computer Consultants VICAR Full A/R System SC 2.3
Printer Parameters:
The following Two must be defined if Ext
Path & Program name to External Support
Printer Path : \·················································
Program Cmd - %F to indicate file 2 use
Printer Cmd. :
Printer Error Codes:
Printer Device : LPT1 Off Line : 0
Def. Report Len : 66 Out Of Paper : 40
Use Form Feeds : No Not On : 200
Write Init. Str : No Not Connected : 48
Use Condensed Print : Yes
F1 - HELP
F2 - Save Changes
<RETURN> for Next Field ESC - To Quit
--------------------------------------------------------------------------------
Figure 17.7.4
CHANGE CONFIGURATION - Printer Parameters Entry - Continued.
Printer Error Codes - See the Section: DETERMINING
PRINTER ERROR CODES before initializing the following
Codes.
Off Line Error Code - This is the Code returned to the
computer by the printer when it is Off Line.
DEFAULT: 0
Out of Paper Error Code - This is the Code returned to the
computer by the printer when it is Out of Paper.
DEFAULT: 40
Not On Error Code - This is the Code received by the
computer when the printer is Not On.
DEFAULT: 200
Not Connected Error Code - This is the Code received by the
computer when the printer is Not plugged into the computer.
DEFAULT: 48
17.7.5 Init. Printer Codes - This is the standard code that is
sent to the printer each time a report, etc. is to be printed.
Any standard features that are desired for printing; such as:
enhanced printing, emphasized printing, 12 CPI, 15 CPI, NLQ,
etc. should be enabled by entering the printer specific print
codes in this code string.
17.7.6 Reset Printer Codes - This is the standard code that is
sent to the printer each time a report, etc. is finished
printing. Any features used in the above code string should be
cancelled with the appropriate reset codes, also you can do a
Form Feed here to avoid using the: Use Form Feed parameter.
17.7.7 Condensed Print Codes - If Condensed printing is desired
for for wide reports on narrow paper, then place the
appropriate printer code here to invoke Condensed Print Mode.
17.7.8 No Condensed Print Codes - If Condensed Print is secified
then the appropriate reset printer code should be entered here.
@PA
CHANGE CONFIGURATION - Printer Codes Entry -
17.7.9 Printer Code String Entry - The current Printer Code
string that is being edited will be displayed above the
editing area. See Figure 17.7.9
To enter a printer code string, enter the decimal values of
the needed character sequence. E.g. ESC ! would be entered
as: 27 33
Editing Keys for code entry are the same as Ptool Ent, with
the following exceptions:
- After each Code Press <ENTER> except after the last code.
- After the Last Code Press <F2> to save codes entered.
- If the code or codes are entered Incorrectly Press <ESC>
to disregard codes entered.
--------------------------------------------------------------------------------
Current Init Code is:
Enter Printer Init Codes:
Enter Decimal Codes one at a time.
F2 to Save, <ESC> to Quit.
Enter Code: 0··
--------------------------------------------------------------------------------
Figure 17.7.9
17.7.10 Write Parameters to Configuration File - selecting this
option will save changes made to the configuration file. If
<F2> was pressed in either of the two Parameter entry Screens
or in any of the Printer Code String entry Screens then the
changes will be saved automatically upon Quiting the
Configuration Main menu.